Specification
Type
|
EA100-1 EAB100-1 |
EA200-1 EAB200-1 |
EA100-1.5 EAB100-1.5 |
EA200-1.5 EAB200-1.5 |
EA100-2 EAB100-2 |
EA200-2 EAB200-2 |
|
|---|---|---|---|---|---|---|---|
| Power source 50/60 Hz | 100V AC±10% | 200V AC±10% | 100V AC±10% | 200V AC±10% | 100V AC±10% | 200 V AC±10% | |
| Rated current | 90mA | 50mA | 90mA | 50mA | 100mA | 50mA | |
| Max. power consumption | 9W | 10W | 9W | 10W | 10W | ||
| Valve closing time 90* | 50Hz | Approx.6 s | Approx.12 s | Approx.15 s | |||
| 60Hz | Approx.5 s | Approx.10 s | Approx.13 s | ||||
| Max. output torque | 1.9Nㆍm | 3.9Nㆍm | 9.8Nㆍm | ||||
| Rated time | Continuous | ||||||
| Insulation class | JIS Class E | ||||||
| Sensitive switch contact capacity | 125V AC 2A (Resistance load) 250V AC 0.6A (Resistance load) |
125V AC 2A (Resistance load) 250V AC 2A (Resistance load) |
|||||
| Position limit switch | One unit each for opening/closing (Voltage output) | ||||||
| Insulation strength | 1500V AC (1 min. interval) | ||||||
| Insulation resistance | Minimum 10MQ (500V DC) | ||||||
| Standard protection | All weather type (for outdoor use, avoid exposure to direct sunlight) IP56 (IEC60529) | ||||||
| Ambient temperature | -20C to +50C | ||||||
| Mounting position | Vertical to horizontal | ||||||
| Wiring | Vinyl cabtyre cord with five cores, 700mm in length 0.3mm2 |
0.5mm2 | |||||
| Lubrication | Grease | ||||||
| Overload protection | Impedance protection | ||||||
| Coating color | Housing: black Cover: light blue | ||||||